[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Indexing & Abstracting::
Publication Ethics::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Indexing & Abstracting
DOAJ
GOOGLE SCHOLAR
..
:: Volume 14, Issue 4 (1-2010) ::
__Armaghane Danesh__ 2010, 14(4): 76-87 Back to browse issues page
Determining the Most Suitable Spirometric Parameters to Differentiate Chronic Obstructive pulmonary Disease (COPD) from Asthma
S Mehrabi , MR Sadin1 , SMA Ghauomi
1- , sadinmr @sums.ac.ir
Abstract:   (7260 Views)
Introduction & Objective: Chronic Obstructive Pulmonary Disease (COPD) and asthma are common diseases with difference in prognosis and treatment. It is believed that spirometry is the best modality for differentiating the two conditions however, the data is heterogeneous. This study aims at determining the most suitable spirometric parameters in this regard. Materials & Methods: In this case control study, fifty patients (25 patients with asthma and 25 patients with COPD) in pulmonology ward of Dr.Faqi’hi Hospital of Shiraz in 2008 under the base spirometry and post bronchodilator were recruited and comparison between these two groups was done. The collected data was analyzed by the SPSS software using independent t-test, Man-Whitney, Chi-square and Fisher test. Results: Frequency of male patients and the mean age were significantly higher in the COPD group. Increase of forced expiratory volume in one second (FEV1) after administration of bronchodilator was significantly higher in asthmatic patients with an optimal cut-off point of ≥0.165 L (15% increase) yielded a sensitivity and specificity of 64% and 60%, respectively. Change of other parameters was not significantly different between the two groups. The best differentiating spirometric parameter was post-inhalation FEV1/predicted value with an optimal cut-off point of ≥64.2, with relating sensitivity and specificity of 88%. Conclusion: According to our results and in concordance to other reports, changing of spirometric parameters after inhalation of a short-acting bronchodilator is not a reliable indicator of asthma or COPD. Post-inhalation FEV1/predicted value is the best parameter in this regard however, the clinical suspicion should not be replaced by it.
Keywords: Asthma, COPD, Spirometry
Full-Text [PDF 177 kb]   (1261 Downloads)    
Type of Study: Research | Subject: Special
Received: 2015/05/27 | Accepted: 2015/05/27 | Published: 2015/05/27
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mehrabi S, Sadin M, Ghauomi S. Determining the Most Suitable Spirometric Parameters to Differentiate Chronic Obstructive pulmonary Disease (COPD) from Asthma. armaghanj 2010; 14 (4) :76-87
URL: http://armaghanj.yums.ac.ir/article-1-589-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 14, Issue 4 (1-2010) Back to browse issues page
ارمغان دانش Armaghane Danesh
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4700